We insist on offering good quality generation with very good business enterprise concept, honest income as well as best and fast assistance. it will bring you not only the premium quality product or service and huge profit, but probably the most significant is usually to occupy the endless market for COVID-19 colloidal gold, COVID-19 lateral flow assay, Candida IgM Antibody Detection Kit (CLIA), We warmly welcome friends from all walks of existence to cooperate with us.
OEM manufacturer carbapenem-resistant enterobacteriaceae - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

The Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) is an immunochromatographic test system intended for the qualitative detection of IMP-type carbapenemase in bacterial colonies. The assay is a prescription-use laboratory assay which can aid in the diagnosis of IMP-type carbapenem resistant strains.

Carbapenem-resistant NDM Detection K-Set (Lateral Flow Assay) 1

Characteristics

Name

Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Bacterial colonies

Specification

25 tests/kit

Detection time

10-15 min

Detection objects

Carbapenem-resistant Enterobacteriaceae (CRE)

Detection type

IMP

Stability

The K-Set is stable for 2 years at 2°C-30°C

Carbapenem-resistant IMP

Advantage

  • Rapid
    Obtain result within 15 min, 3 days earlier than traditional detection methods
  • Simple
    Easy to use, ordinary laboratory staff can operate without training
  • Accurate
    High sensitivity and specificity
    Low detection limit: 0.20 ng/mL
    Able to detect most of the common subtypes of IMP
  • Intuitive result
    There is no need for calculation, visual reading result
  • Economic
    Product can be transported and stored at room temperature, reducing costs

The importance of CRE test

Collectively, Enterobacterales are the most common group of pathogens causing healthcare-associated infections. Some Enterobacterales can produce an enzyme called a carbapenemase that makes antibiotics like carbapenems, penicillins, and cephalosporins ineffective. For this reason, CRE have been called “nightmare bacteria” because there are few alternative antibiotics, if any, left to treat the infections caused by these germs.

Bacteria from the Enterobacterales family, including Klebsiella species and Escherichia coli, can produce a carbapenemase. Carbapenemases are often produced from genes located on transferable elements that can spread resistance easily from germ to germ and person to person. Also because of the abuse usage of antibiotics and limited methods taken to prevent spreading, the dramatically increasing CRE problem is becoming a life threat worldwide.

Usually, spread of CRE can be controlled by:

  • Monitoring CRE infections
  • Isolate patients with CRE
  • Removing invasive medical devices inside the body
  • Be careful when prescribing antibiotics (especially carbapenems)
  • Using clean sterile techniques to minimize the spread of infection
  • Strictly follow the lab cleaning routine

……
CRE detection is of great value in spread control. By testing early, health providers can give a more reasonable therapy to patients susceptible to CRE, also achieve the hospitalization management.

IMP-type carbapenemase

Carbapenemase refers to a type of β-lactamase that can at least significantly hydrolyze imipenem or meropenem, including A, B, D three types of enzymes classified by Ambler molecular structure. Among them, Class B are metallo-β-lactamases (MBLs), including carbapenemases such as IMP, VIM and NDM,. IMP-type carbapenemase, also known as imipenemase metallo-beta-lactamase producing CRE, is a very common kind of acquired MBLs and is from subclass 3A. It can hydrolyze almost all β-lactam antibiotics.

Operation

  • Add 5 drops of sample treatment solution
  • Dip bacterial colonies with a disposable inoculation loop
  • Insert the loop into the tube
  • Add 50 μL to the S well, wait for 10-15 minutes
  • Read the result

Carbapenem-resistant KPC Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

CPI-01

25 tests/kit

CPI-01


Product detail pictures:

OEM manufacturer carbapenem-resistant enterobacteriaceae - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

We constantly think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body along with the living for OEM manufacturer carbapenem-resistant enterobacteriaceae - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Washington, Greece, United States, Nowadays our merchandise sell all over the domestic and abroad thanks for the regular and new customers support. We supply high quality product and competitive price, welcome the regular and new customers cooperate with us!
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Janice from Estonia - 2018.12.10 19:03
    This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Lisa from Poland - 2018.07.12 12:19
    Write your message here and send it to us