Newly Arrival IMP antibiotic resistance - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

We always work as a tangible team to ensure that we can provide you with the best quality and the best price for Aspergillus IgM Antibody Detection K-Set (Lateral Flow Assay), aspergillus IgG testing, drug resistance, We can customize the products according to your requirements and we can pack it for you when you order.
Newly Arrival IMP antibiotic resistance - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

The Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) is an immunochromatographic test system intended for the qualitative detection of VIM-type carbapenemase in bacterial colonies. The assay is a prescription-use laboratory assay which can aid in the diagnosis of VIM-type carbapenem resistant strains.

Carbapenem-resistant NDM Detection K-Set (Lateral Flow Assay) 1

Characteristics

Name

Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Bacterial colonies

Specification

25 tests/kit

Detection time

10-15 min

Detection objects

Carbapenem-resistant Enterobacteriaceae (CRE)

Detection type

VIM

Stability

The K-Set is stable for 2 years at 2°C-30°C

Carbapenem-resistant VIM

Advantage

  • Rapid
    Obtain result within 15 min, 3 days earlier than traditional detection methods
  • Simple
    Easy to use, ordinary laboratory staff can operate without training
  • Accurate
    High sensitivity and specificity
    Low detection limit: 0.20 ng/mL
    Able to detect most of the common subtypes of VIM
  • Intuitive result
    There is no need for calculation, visual reading result
  • Economic
    Product can be transported and stored at room temperature, reducing costs

The importance of CRE test

Carbapenem-resistant Enterobacteriaceae (CRE) are part of a group of germs that live in the intestines of some people. They’re related to E. coli, but it is normal to have E. coli in your intestine and stool. The problem happens when these germs mutate and become resistant to antibiotics. Some CRE are resistant to so many medications that they are untreatable, and up to half of patients infected may die. This is particularly worrisome because carbapenems used to be one of the only antibiotics that could successfully treat another Enterobacter “superbugs.”

Common methods taken to control the spread of CRE:

  • Strict CRE infection monitoring
  • Patients’ isolation before and during hospitalization
  • Take caution when prescribing antibiotics, avoid drug abuse
  • Use sterile techniques, wash hands and avoid being inside ICU for too long

……
That is why the early typing of CRE subtypes are important in clinical CRE control. The rapid and accurate CRE test kits can help with medical prescription, patient management, thus minimize the increase speed of antibiotics resistance.

VIM-Type Carbapenemase

Carbapenemase is a type of β-lactamase that can at least significantly hydrolyze imipenem or meropenem, including A, B, D three types. In these types, Class B are metallo-β-lactamases (MBLs), including carbapenemases such as IMP, VIM and NDM, which were mainly found in Pseudomonas aeruginosa, Acinetobacteria and Enterobacteriaceae bacteria. Verona Integron-encoded Metallo-beta-lactamase (VIM) is the most frequently-encountered carbapenemase in P. aeruginosa3. Among variants, the VIM-2 metallo-beta-lactamase exhibits the broadest geographical distribution, including on the European continent.

Operation

  • Add 5 drops of sample treatment solution
  • Dip bacterial colonies with a disposable inoculation loop
  • Insert the loop into the tube
  • Add 50 μL to the S well, wait for 10-15 minutes
  • Read the result

Carbapenem-resistant KPC Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

CPV-01

25 tests/kit

CPV-01


Product detail pictures:

Newly Arrival IMP antibiotic resistance - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Newly Arrival IMP antibiotic resistance - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: US, Singapore, Karachi, In order to carry out our goal of "customer first and mutual benefit" in the cooperation, we establish a specialist engineering team and a sales team to supply the best service to satisfy our customers' requirements. Welcome you to cooperate with us and join us. We have been your best choice.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Frederica from Afghanistan - 2018.09.29 13:24
    Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By John from Jersey - 2017.02.28 14:19
    Write your message here and send it to us