Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

As for competitive charges, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we have been the lowest around for OXA-48, COVID-19 IgM/IgG Lateral Flow Assay, 2019-nCoV antigen test, We, with fantastic passion and faithfulness, are willing to offer you with best services and striding forward with you to make a bright foreseeable future.
Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio Detail:

Product Introduction

FungiXpert® Fungus (1-3)-β-D-Glucan Detection Kit (Chromogenic Method) is intended for the screening diagnosis of invasive fungal disease. It is used to provide rapid diagnostic reference for clinical invasive fungal infections through quantitative detection of (1-3)-β-D-glucan in the serum and Bronchoalveolar Lavage (BAL) fluid. GCT-110T series are intended for manual operation with microplate reader. GKT-5M/10M are used with our semi-automated instrument MB80 series and fully automated instrument IGL series.

Characteristics

Name

Fungus (1-3)-β-D-Glucan Detection Kit (Chromogenic Method)

Model

GCT-110T

GKT-25M

GKT-12M

GKT-10M

GKT-5M

Specification

110 tests/kit

50 tests/kit

50 tests/kit

36 tests/kit

30 tests/kit

Detection time

40 min

60 min

Instrument

Microplate Reader

Kinetic Tube Reader

Method

Chromogenic Method

Sample type

Serum, BAL fluid

Detection objects

Invasive fungi

Linearity range

31.25-500 pg/mL

Stability

Stable for 3 years at 2-8°C in the dark

Advantages

  • Methodology advantages
    Obtain results in 40-60 min, 5-8 days prior to clinical symptoms and imaging
    Recommended by the EORTC/MSG Consensus Group as one of the mycological criteria for the diagnosis of invasive fungal disease
  • More options available:
    Automated instruments / Manual operation
    Larger / smaller throughput
    Customization service
  • Quality controls are provided with the kit
    More reliable experimental accuracy
  • Compatible with Automatic instruments
    Can be equipped with fully automatic instruments, easy and reduce errors
    Fully Automatic Kinetic Tube Reader (IGL-200)
    Fully Automatic Kinetic Tube Reader (IGL-800)
    Kinetic Tube Reader (MB-80M)
    Kinetic Tube Reader (MB-80A)
    Kinetic Tube Reader (MB-80X)
  • Good manufacture quality and ability
    Total manufacture from principal raw materials to finished products.
    In 2017, Era Biology, as a leader and pioneer in the industry, participated in drafting the industry standard of “Fungus(1-3)-B-D-Glucan Test” with National Center for Clinical Laboratories etc.

Principle of BDG test

Fungus (1-3)-B-D-Glucan (BDG) is a unique element of fungal cell wall, when the fungus invades blood or deep tissue, BDG can be released from the cell wall.

Applicable departments

Order Information

Model

Description

Product code

GCT-110T

110 tests/kit, used with Microplate Reader

BG110-001

GKT-12M

50 tests/kit, used with automated Kinetic Tube Reader

BG050-001

GKT-25M

50 tests/kit, used with automated Kinetic Tube Reader

BG050-002

GKT-5M

30 tests/kit, used with automated Kinetic Tube Reader

BG030-001

GKT-10M

36 tests/kit, used with automated Kinetic Tube Reader

BG030-002


Product detail pictures:

Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures


Related Product Guide:

To create much more price for clients is our company philosophy; purchaser growing is our working chase for Factory Outlets Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio , The product will supply to all over the world, such as: Brazil, Philippines, Benin, Make sure you genuinely feel free to send us your requirements and we are going to respond for you asap. We now have got a skilled engineering group to serve for your just about every detailed needs. Cost-free samples could be sent to suit your needs personally to understand much more information. In an effort to meet your requires, be sure to seriously feel free to make contact with us. You may send us emails and contact us directly. Moreover, we welcome visits to our factory from around the globe for much better recognizing of our organization. nd objects. In our trade with merchants of numerous countries, we usually adhere for the principle of equality and mutual benefit. It is really our hope to market, by joint efforts, each trade and friendship to our mutual advantage. We look forward to getting your inquiries.
  • The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Afra from Cyprus - 2017.09.26 12:12
    We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Diego from Hyderabad - 2017.06.19 13:51
    Write your message here and send it to us