Factory making bacteria test kit - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and superb good quality control throughout all stages of manufacturing enables us to guarantee total buyer gratification for Procalcitonin test, CRE detection, IMP carbapenemase, We also ensure that your choice is going to be crafted with the highest good quality and dependability. Be sure to feel free of charge to contact us for additional information.
Factory making bacteria test kit - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

FungiXpert® Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) uses colloidal gold immunochromatography technology to detect aspergillus-specific IgG antibody in human serum, providing a rapid and effective auxiliary aid for the diagnosis of susceptible populations.

Invasive fungal diseases (IFD) have become one of the biggest life threats to immunocompromised patients and have caused high morality worldwide. Aspergillus species are ubiquitous, saprophytic fungi that are important causes of morbidity and mortality in transplant recipients. Humans become infected with Aspergillus after conidia are inhaled and deposited in bronchioles, in alveolar spaces, and less commonly in paranasal sinuses. Most common Aspergillus pathogens include Aspergillus fumigatus, Aspergillus flavus, Aspergillus niger, Aspergillus terreus.

Chronic pulmonary aspergillosis (CPA) is an underdiagnosed and misdiagnosed disease and now increasingly recognised. However, the diagnosis of CPA remains challenging. Recent studies have found the diagnostic values of serum Aspergillus-specific IgG and IgM antibodies in patients with CPA. The Infectious Diseases Society of America (IDSA) have recommended that Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA).

Characteristics

Name

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Serum

Specification

25 tests/kit; 50 tests/kit

Detection time

10 min

Detection objects

Aspergillus spp.

Stability

The K-Set is stable for 2 years at 2-30°C

Low detection limit

5 AU/mL

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay)

Advantage

  • Simple and accurate
    Easy to use, ordinary laboratory staff can operate without training
    Intuitive and visual reading result
  • Accurate and economical
    Low detection limit: 5 AU/mL
    Transported and stored at room temperature, reducing costs
  • Rapid and convenient
    Obtain result within 10 min
    Two specifications available: cassette/25T; strip/50T
  • Support the diagnosis of aspergillosis in early stage
    Aspergillus-specific IgG antibodies take a mean of 10.8 days to appear in acute illness
  • Detection of single immunoglobulin subtype demonstrate the infection stage
    Relationship between antibody concentration and Aspergillus infection

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 1

  • Recommended by ESCMID/ECMM/ERS/IDSA etc
    IgG antibody response to Aspergillus spp. is one of the characteristics required for the diagnosis of CPA.
    Aspergillus IgG antibody elevated or other microbiological data is one of the necessary evidences for the diagnosis of chronic cavitary pulmonary aspergillosis (CCPA)
    Antibody diagnosis of chronic pulmonary aspergillosis (CPA)
Population Intention Intervention SoR QoE
Cavitary or nodular pulmonary infiltrate in
non-immunocompromised patients
Diagnosis or exclusion of CPA Aspergillus IgG antibody A II
  • Applicable department

Respiration department
Cancer department
Hematology department

ICU
Transplantation department
Infectious department

Operation

Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 3
Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

AGLFA-01

25 tests/kit, cassette format

FGM025-002

AGLFA-02

50 tests/kit, strip format

FGM050-002


Product detail pictures:

Factory making bacteria test kit - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Factory making bacteria test kit - Aspergillus IgG Antibody Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Mumbai, Doha, Tajikistan, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we'll continue to develop, to supply the high-quality goods and services, and promote lasting cooperation with our customers, common development and create a better future.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Albert from Marseille - 2018.06.30 17:29
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Eleanore from Hyderabad - 2018.11.11 19:52
    Write your message here and send it to us