Factory Free sample CRP, CRP detection - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

"Control the quality by the details, show the strength by quality". Our company has strived to establish a highly efficient and stable staff team and explored an effective quality control process for SARS-CoV-2 antibody, Serum Amyloid (SAA) Detection Kit (CLIA), SARS-CoV-2 nuclear acid, On account of superior quality and competitive price , we will be the market leader, please don’t hesitate to contact us by phone or email, if you are interested in any of our products.
Factory Free sample CRP, CRP detection - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

The Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) is an immunochromatographic test system intended for the qualitative detection of IMP-type carbapenemase in bacterial colonies. The assay is a prescription-use laboratory assay which can aid in the diagnosis of IMP-type carbapenem resistant strains.

Carbapenem-resistant NDM Detection K-Set (Lateral Flow Assay) 1

Characteristics

Name

Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Bacterial colonies

Specification

25 tests/kit

Detection time

10-15 min

Detection objects

Carbapenem-resistant Enterobacteriaceae (CRE)

Detection type

IMP

Stability

The K-Set is stable for 2 years at 2°C-30°C

Carbapenem-resistant IMP

Advantage

  • Rapid
    Obtain result within 15 min, 3 days earlier than traditional detection methods
  • Simple
    Easy to use, ordinary laboratory staff can operate without training
  • Accurate
    High sensitivity and specificity
    Low detection limit: 0.20 ng/mL
    Able to detect most of the common subtypes of IMP
  • Intuitive result
    There is no need for calculation, visual reading result
  • Economic
    Product can be transported and stored at room temperature, reducing costs

The importance of CRE test

Collectively, Enterobacterales are the most common group of pathogens causing healthcare-associated infections. Some Enterobacterales can produce an enzyme called a carbapenemase that makes antibiotics like carbapenems, penicillins, and cephalosporins ineffective. For this reason, CRE have been called “nightmare bacteria” because there are few alternative antibiotics, if any, left to treat the infections caused by these germs.

Bacteria from the Enterobacterales family, including Klebsiella species and Escherichia coli, can produce a carbapenemase. Carbapenemases are often produced from genes located on transferable elements that can spread resistance easily from germ to germ and person to person. Also because of the abuse usage of antibiotics and limited methods taken to prevent spreading, the dramatically increasing CRE problem is becoming a life threat worldwide.

Usually, spread of CRE can be controlled by:

  • Monitoring CRE infections
  • Isolate patients with CRE
  • Removing invasive medical devices inside the body
  • Be careful when prescribing antibiotics (especially carbapenems)
  • Using clean sterile techniques to minimize the spread of infection
  • Strictly follow the lab cleaning routine

……
CRE detection is of great value in spread control. By testing early, health providers can give a more reasonable therapy to patients susceptible to CRE, also achieve the hospitalization management.

IMP-type carbapenemase

Carbapenemase refers to a type of β-lactamase that can at least significantly hydrolyze imipenem or meropenem, including A, B, D three types of enzymes classified by Ambler molecular structure. Among them, Class B are metallo-β-lactamases (MBLs), including carbapenemases such as IMP, VIM and NDM,. IMP-type carbapenemase, also known as imipenemase metallo-beta-lactamase producing CRE, is a very common kind of acquired MBLs and is from subclass 3A. It can hydrolyze almost all β-lactam antibiotics.

Operation

  • Add 5 drops of sample treatment solution
  • Dip bacterial colonies with a disposable inoculation loop
  • Insert the loop into the tube
  • Add 50 μL to the S well, wait for 10-15 minutes
  • Read the result

Carbapenem-resistant KPC Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

CPI-01

25 tests/kit

CPI-01


Product detail pictures:

Factory Free sample CRP, CRP detection - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

With responsible good quality method, good status and excellent client services, the series of solutions produced by our company are exported to lots of countries and regions for Factory Free sample CRP, CRP detection - Carbapenem-resistant IMP Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Botswana, Mozambique, Uruguay, Our products are produced with the best raw materials. Every moment, we constantly improve the production programme. In order to ensure better quality and service, we have been focusing on the production process. We have got high praise by partner. We are looking forward to establishing business relationship with you.
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Paula from Argentina - 2018.12.10 19:03
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Helen from Algeria - 2018.08.12 12:27
    Write your message here and send it to us