factory customized aspergillus galactomannan antigen - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for automated glucan test, COVID-19 RBD antibody, COVID-19 IgG, We are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more detail!
factory customized aspergillus galactomannan antigen - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio Detail:

Product Introduction

The Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) is an immunochromatographic test system intended for the qualitative detection of VIM-type carbapenemase in bacterial colonies. The assay is a prescription-use laboratory assay which can aid in the diagnosis of VIM-type carbapenem resistant strains.

Carbapenem-resistant NDM Detection K-Set (Lateral Flow Assay) 1

Characteristics

Name

Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Bacterial colonies

Specification

25 tests/kit

Detection time

10-15 min

Detection objects

Carbapenem-resistant Enterobacteriaceae (CRE)

Detection type

VIM

Stability

The K-Set is stable for 2 years at 2°C-30°C

Carbapenem-resistant VIM

Advantage

  • Rapid
    Obtain result within 15 min, 3 days earlier than traditional detection methods
  • Simple
    Easy to use, ordinary laboratory staff can operate without training
  • Accurate
    High sensitivity and specificity
    Low detection limit: 0.20 ng/mL
    Able to detect most of the common subtypes of VIM
  • Intuitive result
    There is no need for calculation, visual reading result
  • Economic
    Product can be transported and stored at room temperature, reducing costs

The importance of CRE test

Carbapenem-resistant Enterobacteriaceae (CRE) are part of a group of germs that live in the intestines of some people. They’re related to E. coli, but it is normal to have E. coli in your intestine and stool. The problem happens when these germs mutate and become resistant to antibiotics. Some CRE are resistant to so many medications that they are untreatable, and up to half of patients infected may die. This is particularly worrisome because carbapenems used to be one of the only antibiotics that could successfully treat another Enterobacter “superbugs.”

Common methods taken to control the spread of CRE:

  • Strict CRE infection monitoring
  • Patients’ isolation before and during hospitalization
  • Take caution when prescribing antibiotics, avoid drug abuse
  • Use sterile techniques, wash hands and avoid being inside ICU for too long

……
That is why the early typing of CRE subtypes are important in clinical CRE control. The rapid and accurate CRE test kits can help with medical prescription, patient management, thus minimize the increase speed of antibiotics resistance.

VIM-Type Carbapenemase

Carbapenemase is a type of β-lactamase that can at least significantly hydrolyze imipenem or meropenem, including A, B, D three types. In these types, Class B are metallo-β-lactamases (MBLs), including carbapenemases such as IMP, VIM and NDM, which were mainly found in Pseudomonas aeruginosa, Acinetobacteria and Enterobacteriaceae bacteria. Verona Integron-encoded Metallo-beta-lactamase (VIM) is the most frequently-encountered carbapenemase in P. aeruginosa3. Among variants, the VIM-2 metallo-beta-lactamase exhibits the broadest geographical distribution, including on the European continent.

Operation

  • Add 5 drops of sample treatment solution
  • Dip bacterial colonies with a disposable inoculation loop
  • Insert the loop into the tube
  • Add 50 μL to the S well, wait for 10-15 minutes
  • Read the result

Carbapenem-resistant KPC Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

CPV-01

25 tests/kit

CPV-01


Product detail pictures:

factory customized aspergillus galactomannan antigen - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio detail pictures


Related Product Guide:

Our firm aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine regularly for factory customized aspergillus galactomannan antigen - Carbapenem-resistant VIM Detection K-Set (Lateral Flow Assay) – Genobio , The product will supply to all over the world, such as: Swiss, Nepal, Switzerland, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Allow us to work together to write a brilliant new chapter!
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Mona from Jeddah - 2018.10.01 14:14
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Esther from Serbia - 2018.04.25 16:46
    Write your message here and send it to us