China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio


Product Detail

Product Tags

Related Video

Feedback (2)

We not only will try our greatest to offer you excellent services to each individual client, but also are ready to receive any suggestion offered by our buyers for COVID-19 molecular diagnostics, bacterial endotoxin chemiluminescence immunoassay, LAL test, Our merchandise are widely recognized and dependable by users and can meet continuously building economic and social needs.
China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio Detail:

Product Introduction

FungiXpert® Fungus (1-3)-β-D-Glucan Detection Kit (Chromogenic Method) is intended for the screening diagnosis of invasive fungal disease. It is used to provide rapid diagnostic reference for clinical invasive fungal infections through quantitative detection of (1-3)-β-D-glucan in the serum and Bronchoalveolar Lavage (BAL) fluid. GCT-110T series are intended for manual operation with microplate reader. GKT-5M/10M are used with our semi-automated instrument MB80 series and fully automated instrument IGL series.

Characteristics

Name

Fungus (1-3)-β-D-Glucan Detection Kit (Chromogenic Method)

Model

GCT-110T

GKT-25M

GKT-12M

GKT-10M

GKT-5M

Specification

110 tests/kit

50 tests/kit

50 tests/kit

36 tests/kit

30 tests/kit

Detection time

40 min

60 min

Instrument

Microplate Reader

Kinetic Tube Reader

Method

Chromogenic Method

Sample type

Serum, BAL fluid

Detection objects

Invasive fungi

Linearity range

31.25-500 pg/mL

Stability

Stable for 3 years at 2-8°C in the dark

Advantages

  • Methodology advantages
    Obtain results in 40-60 min, 5-8 days prior to clinical symptoms and imaging
    Recommended by the EORTC/MSG Consensus Group as one of the mycological criteria for the diagnosis of invasive fungal disease
  • More options available:
    Automated instruments / Manual operation
    Larger / smaller throughput
    Customization service
  • Quality controls are provided with the kit
    More reliable experimental accuracy
  • Compatible with Automatic instruments
    Can be equipped with fully automatic instruments, easy and reduce errors
    Fully Automatic Kinetic Tube Reader (IGL-200)
    Fully Automatic Kinetic Tube Reader (IGL-800)
    Kinetic Tube Reader (MB-80M)
    Kinetic Tube Reader (MB-80A)
    Kinetic Tube Reader (MB-80X)
  • Good manufacture quality and ability
    Total manufacture from principal raw materials to finished products.
    In 2017, Era Biology, as a leader and pioneer in the industry, participated in drafting the industry standard of “Fungus(1-3)-B-D-Glucan Test” with National Center for Clinical Laboratories etc.

Principle of BDG test

Fungus (1-3)-B-D-Glucan (BDG) is a unique element of fungal cell wall, when the fungus invades blood or deep tissue, BDG can be released from the cell wall.

Applicable departments

Order Information

Model

Description

Product code

GCT-110T

110 tests/kit, used with Microplate Reader

BG110-001

GKT-12M

50 tests/kit, used with automated Kinetic Tube Reader

BG050-001

GKT-25M

50 tests/kit, used with automated Kinetic Tube Reader

BG050-002

GKT-5M

30 tests/kit, used with automated Kinetic Tube Reader

BG030-001

GKT-10M

36 tests/kit, used with automated Kinetic Tube Reader

BG030-002


Product detail pictures:

China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures

China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio detail pictures


Related Product Guide:

The organization keeps on the procedure concept "scientific management, high quality and efficiency primacy, purchaser supreme for China Factory for Candida Mannan Detection K-Set (Lateral Flow Assay) - Fungus (1-3)-β-D-Glucan Test (Chromogenic Method) – Genobio , The product will supply to all over the world, such as: Peru, European, St. Petersburg, Our company abides by the management idea of "keep innovation, pursue excellence". On the basis of assuring the advantages of existing merchandise, we continuously strengthen and extend product development. Our company insists on innovation to promote the sustainable development of enterprise, and make us become the domestic high-quality suppliers.
  • High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Maureen from Ecuador - 2017.08.18 11:04
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By jari dedenroth from Ireland - 2018.06.09 12:42
    Write your message here and send it to us