Candida Mannan IgM Antibody Detection K-Set (Lateral Flow Assay)

Rapid test for anti-candida IgM within 10 min

Detection objects Candida spp.
Methodology Lateral Flow Assay
Sample type Serum
Specifications 25 tests/kit, 50 tests/kit
Product code FM025-003, FM050-003

Product Detail

Product Tags

Product Introduction

FungiXpert® Candida Mannan IgM Antibody Detection K-Set (Lateral Flow Assay) is used for in vitro qualitative detection of the Candida mannan IgM antibody in serum, providing a rapid and effective auxiliary method for the diagnosis of susceptible population.

Candida is a type of yeast that causes the majority of fungal infections. Candida albicans is the most abundant invading strain that can be offensive to the body, in the presence of predisposing factors. When the candida infection occurs, IgM antibody is the first antibody released, following any first-time exposure to a certain antigen. Once formed, it activates the compliment and initiate the phagocytic system to help the body getting rid of invading antigens. IgM are specific to our intravascularly tissues.

They are the most predominant immunoglobulins released upon any early infection. Detection of candida IgM antibody, as well as its combination with IgG antibody detection, is of great value on the diagnosis and stage determination of invasive candidiasis infection.

Characteristics

Name

Candida Mannan IgM Antibody Detection K-Set (Lateral Flow Assay)

Method

Lateral Flow Assay

Sample type

Serum

Specification

25 tests/kit; 50 tests/kit

Detection time

10 min

Detection objects

Candida spp.

Stability

The K-Set is stable for 2 years at 2-30°C

Low detection limit

4 AU/mL

Candida Mannan IgM

Advantage

  • Simple and accurate
    Clinicians can perform tests without training of operation, easy and fast
    Visual reading result – Test line & Control line
  • Rapid and convenient
    10 min to obtain result
    Two models: cassette: 25 Tests/kit; strip: 50 Tests/kit
  • Early diagnosis
    Early before the culture results about 7 days for Candidemia
    Early before radiological detection about 16 days for the patients with hepatosplenic IC
    It can help physicians in initiating prompt and appropriate antifungal therapy, resulting in life saving and decreased morbidity
  • Economical
    Product can be transported and stored at room temperature, reducing costs

Operation

Candida Mannan IgM Antibody Detection K-Set (Lateral Flow Assay) 1
Candida Mannan IgM Antibody Detection K-Set (Lateral Flow Assay) 2

Order Information

Model

Description

Product code

CMLFA-01

25 tests/kit, cassette format

FM025-003

CMLFA-02

50 tests/kit, strip format

FM050-003


  • Previous:
  • Next:

  • Write your message here and send it to us